B3000 SE Regular Cab 2WD V6-3.0L OHV (2002)
Coolant Reservoir: Service and Repair
COOLANT RECOVERY RESERVOIR REMOVAL / INSTALLATION
1. Remove the air cleaner outlet tube.
2. Disconnect the connector.
3. Disconnect the overflow hose at the coolant recovery reservoir and drain coolant from coolant recovery reservoir.
4. Remove the two nuts and two bolts.
5. Disconnect the washer motor hose.
6. Remove the coolant recovery reservoir.
7. Install in reverse order of removal.
Tightening torque 6 - 8 Nm {61 - 82 kgf-cm, 54 - 70 inch lbs.)
8. Fill the coolant recovery reservoir to the cold fill mark.