B3000 SE Regular Cab 2WD V6-3.0L OHV (2002)
7. Holding the special tool T-handle stationary, rotate the special tool body to remove the broken evaporator core orifice.
Installation Note
1. Lubricate the refrigerant system with the correct amount of clean refrigerant oil. See REFRIGERANT OIL ADDITION.
2. Install new O-ring seals on the evaporator core orifice.
-
Lubricate the O-ring seals with clean refrigerant oil.
3. Position the evaporator core orifice into the special tool.
4. Using the special tool, install the evaporator core orifice.
5. Connect the condenser to evaporator line spring lock coupling to the evaporator inlet. See SPRING LOCK COUPLING. Restore any components
that were removed for access.
-
Install new O-ring seals lubricated with clean refrigerant oil.
6. Evacuate, leak test, and charge the refrigerant system. See REFRIGERANT SYSTEM TESTS.