B4000 V6-4.0L SOHC (2005)
8. Remove the accessory bracket bolts and position the bracket aside.
9. Disconnect the generator wiring and position the wiring aside.
10. Remove the wiring harness retainer.
11. Remove the generator mounting bracket and generator as an assembly (1). Remove the bolt and the drive belt tensioner. (2). Remove the bolts and
the generator mounting bracket.