B4000 V6-4.0L SOHC (2005)
Air Duct: Service and Repair
Windshield Defroster and Side Window Demister Nozzles Removal / Installation
WINDSHIELD DEFROSTER AND SIDE WINDOW DEMISTER NOZZLES REMOVAL / INSTALLATION
1. Remove the instrument panel (1).
2. Remove the two screws and remove the LH side window demister hose (2) and duct (3).
Tightening Torque: 2 - 3 N.m {20 - 30 kgf.cm, 18 - 26 in.lbf}.
3. Remove the two screws and remove the RH side window demister hose (4) and duct (5).
Tightening Torque: 2 - 3 N.m {20 - 30 kgf.cm, 18 - 26 in.lbf}.
4. Remove the screws and remove the windshield defroster hose nozzle (6).
Tightening Torque: 2 - 3 N.m {20 - 30 kgf.cm, 18 - 26 in.lbf}.
5. Install in reverse order of removal.