Maintenance Free Battery - Diagnostic/Charge Procedure|Page 3790 > < Maintenance Free Battery - Diagnostic/Charge Procedure|Page 3788
Page 7
background image

Diagnostic procedures used for testing lead-acid batteries provide false readings leading to unnecessary replacement if used on maintenance-free
batteries. The information below is provided for diagnosing maintenance-free batteries.

*CAUTION

DO NOT BOOST OR QUICK CHARGE MX-5 MIATA "GEL-TYPE" BATTERIES.

7a. Battery Diagnostic Procedures

(USING Midtronics PowerSensor Plus Tester)

1.

Connect the Midtronics PowerSensor Plus tester. If low voltage is found (less than 10.2V) charge the battery for two (2) hours and recheck. If the
voltage is greater than 10.2V, test battery condition without precharging. If low voltage is still found after a two (2) hour charge, replace the
battery according to the information in the warranty section of this bulletin.

2.

If the tester indicates that the battery is not at fault, refer to the appropriate workshop manual or BETM (Body Electrical Troubleshooting Manual)
for troubleshooting and repair information.

The following are additional Midtronics PowerSensor Plus tester features:

Position "A" will test for an open circuit (bad cell or broken internal circuit). This is indicated by a "Red" LED light. If an open circuit is indicated,
replace the battery using the criteria described in the warranty section of this bulletin.

Position "B" a "green" LED indicates that the battery has at least 10.2V and can therefore be tested without precharging. This position requires that the
OCA rating (for the specific battery type under test) be set on the Midtronics PowerSensor Plus Tester dial. Refer to the chart (Wet Battery Application
Guide) to determine CCA. The Midtronics PowerSensor Plus tester then determines actual CCA by measuring the condition of the battery voltage and
plate condition.

Maintenance Free Battery - Diagnostic/Charge Procedure|Page 3790 > < Maintenance Free Battery - Diagnostic/Charge Procedure|Page 3788