mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Oxygen Sensor|Locations|Page 2342 > < Oxygen Sensor|Locations|Page 2340
Page 1
background image

Oxygen Sensor: Testing and Inspection

Testing Oxygen Sensor

1.   Warm up engine and run it idle.
2.   Disconnect oxygen sensor wiring harness connector.
3.   Connect a voltmeter between oxygen sensor connector (oxygen sensor side) and ground.
4.   Run engine at 4,500 rpm until voltmeter indicates approx. 0.7 volts.
5.   Increase and decrease engine speed suddenly several times.  When speed is increased, check that voltmeter reads between 0.5 and 1.0 volts.  When

speed is decreased, check that voltmeter reads between 0 and 0.4 volts.  Reconnect oxygen sensor connector.

6.   If not as specified, replace oxygen sensor.

Engine Monitor Installed

7.   Connect self diagnosis tester to check connector and negative battery terminal.

NOTE:  Do not ground test connector (Green:1-pin) during this test.

8.   Increase the engine speed to between 2,000 and 3,000 rpm and check that monitor lamp flashes for 10 seconds. It should flash eight or more times

in the ten second period. Disconnect diagnostic tester.

Oxygen sensor input voltage can be check at ECU terminal 2N.

Oxygen Sensor|Locations|Page 2342 > < Oxygen Sensor|Locations|Page 2340