CX-7 AWD L4-2.3L Turbo (2008)
Leak Detection Pump: Testing and Inspection
EVAPORATIVE EMISSION (EVAP) SYSTEM LEAK DETECTION PUMP INSPECTION[L3 WITH TC]
Airflow Inspection
NOTE: Perform the following test only when directed.
1. Disconnect the negative battery cable.
2. Remove the EVAP system leak detection pump.
3. Blow air into port A and verify that there is airflow from port B.
-
If not as specified, replace the EVAP system leak detection pump.
4. Blow air into port B and verify that there is airflow from port A.
-
If not as specified, replace the EVAP system leak detection pump.
-
If as specified, perform the following "Resistance Inspection".
Resistance Inspection
NOTE: Perform the following procedure only when directed.
1. Disconnect the negative battery cable
2. Inspect resistance of the EVAP system leak detection pump.
-
It not as specified, replace the EVAP system leak detection pump.
-
If as specified, carry out the "Circuit Open/Short Inspection".
Circuit Open/Short Inspection