Oxygen Sensor: All Technical Service Bulletins
Engine Controls - O2 Sensor Removal Precautions

Bulletin No: 01-032/10 
Last Issued: 05/27/2010

Subject:
OXYGEN / AIR FUEL RATIO SENSOR REMOVAL CAUTION

*BULLETIN NOTE

^

This bulletin supersedes the previous bulletins 01-019/07 issued 05/10/07, 01-006/08 issued 02/11/08 and 10/10/08, 01-051/09 issued 11/19/09.

^

Changes are noted by asterisks.*

APPLICABLE MODEL(S)/VINS

1997-2003 Protege

1997-2005 Miata

1997-2002 626

1997-2002 Millenia

1997-2006 MPV

2001-2006 Tribute

2008-2010 Tribute

2008-2010 Tribute Hybrid

2003-2010 Mazda6

2004-2010 Mazda3

2004-2010 RX-8

2006-2010 Mazda5

2006-2010 MX-5

2007-2010 CX-7

2007-2010 CX-9

DESCRIPTION

Use the following repair procedure to minimize the need to replace the catalyst converter/exhaust pipe when removing oxygen sensors and/or air fuel
ratio sensors.

REPAIR PROCEDURE

Oxygen Sensor Removal Procedure

WARNING:

To avoid personal injury, allow exhaust system to cool down before removing oxygen sensor.

NOTE:

In some cases oxygen sensor and/or air fuel ratio sensor seizure will occur during this removal procedure. If seizure occurs, remove the converter or
exhaust pipe from the vehicle and re-attempt removal with the assembly placed in a vise. This will maximize your positioning and ability to apply
adequate torque to remove the sensor.

1. If reusing oxygen sensor, mask it with masking tape to prevent lubrication soaking.

Engine Controls - O2 Sensor Removal Precautions|Page 641 > < Engine Controls - Hesitation/Surge/MIL/O2 Sensor DTC's|Page 636