mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Oil Pressure Switch (For Fuel Pump) > < Air Flow Meter/Sensor|Locations|Page 721
Page 2
background image

3. Inspect the following wiring harnesses for an open or short circuit. (Continuity check)

Open circuit

-

If there is no continuity, there is an open circuit. Repair or replace the wiring harness.
-

MAF/IAT sensor terminal A and main relay terminal E

-

MAF/IAT sensor terminal B and PCM terminal 1P

-

MAF/IAT sensor terminal C and PCM terminal 1AK

Short circuit

-

If there is continuity, there is a short circuit. Repair or replace the wiring harness.
-

MAF/IAT sensor terminal A and body ground

-

MAF/IAT sensor terminal B and power supply

-

MAF/IAT sensor terminal C and power supply

-

MAF/IAT sensor terminal C and body ground

Oil Pressure Switch (For Fuel Pump) > < Air Flow Meter/Sensor|Locations|Page 721