Battery: Testing and Inspection

BATTERY INSPECTION[L3 WITH TC]

WARNING:

-

Since battery acid is toxic, be careful when handling the battery.

-

Since battery acid is highly corrosive, be careful not to allow it to contact clothing or the vehicle.

-

In case battery acid contacts skin, eyes, or clothing, flush it immediately with running water. Especially if the acid gets in the eyes, flush
with water for more than 15 min and get prompt medical attention.

Electrolyte Specific Gravity

1. Measure the electrolyte specific gravity using a hydrometer.

-

If it is less than the specification, recharge the battery. (See BATTERY RECHARGING[L3 WITH TC].)

Battery electrolyte specific gravity [20 °C {68 °F}]
1.22-1.29

Battery Voltage

Back-up Current

1. Verify that the ignition switch is off (key has been removed) and that all doors are closed.
2. Disconnect the negative battery cable.
3. Connect the tester between the negative battery terminal and negative battery cable, leave the battery undisturbed for 

30 min, and then measure the

back-up current.
-

If not within the specification, measure the back-up current while removing the fuses one by one from the inside of the main fuse block and the
inside of the fuse block.

NOTE:
-

If the battery is not left undisturbed for 

30 min, the tester will indicate a high value (approx. 300 mA).

-

If the key or any electrical accessory is operated within 

approx. 30 min after the tester is connected, the battery must be left undisturbed for 

approx. 30 min from that point.

CAUTION:  Operating electrical loads while the back-up current is being measured can damage the tester.

NOTE:  For vehicles with the immobilizer system, the system periodically shifts synchronization of the security light flashing. Therefore, 65 mA
(0.1 s)
 current is supplied when the security light is illuminated, and 65 mA (2 s) current is supplied when the security light is not illuminated. In