Inspection item

-

Keyless control module connector

-

Wiring harness between keyless control module terminal 3X and branch H

-

Wiring harness between keyless control module terminal 3W and branch H

-

Keyless control module

Q

Possible cause

-

Connector terminal disconnection, poor contact, damage, deformation, corrosion

-

Open circuit in wiring harness between branch H and instrument cluster

-

Instrument cluster malfunction

System wiring diagram