mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Front Heated Oxygen Sensor (HO2S) Inspection|Page 2365 > < Front Heated Oxygen Sensor (HO2S) Inspection|Page 2363
Page 2
background image

-

If it is not within the specification, replace the HO2S.

-

If the monitor item status/specification (reference) is not within the specification, even though the resistance is within the specification,
perform the "Circuit Open/Short Inspection".

HO2S heater resistance

3-30 ohms

Circuit Open/Short Inspection

1. Disconnect the PCM connector.
2. Inspect the following wiring harness for open or short (continuity check).

Open circuit

-

If there is no continuity, the circuit is open. Repair or replace the harness.
-

HO2S (RH) terminal A and PCM terminal 2AS

-

HO2S (RH) terminal B and PCM terminal 2BG

-

HO2S (RH) terminal C and main relay No.2 terminal D

-

HO2S (RH) terminal D and PCM terminal 2AL

-

HO2S (LH) terminal A and PCM terminal 2AO

-

HO2S (LH) terminal B and PCM terminal 2BC

-

HO2S (LH) terminal C and main relay No.2 terminal D

-

HO2S (LH) terminal D and PCM terminal 2AL

Short circuit

-

If there is continuity, the circuit is shorted. Repair or replace the harness.
-

HO2S (RH) terminal A and power supply

-

HO2S (RH) terminal A and body ground

-

HO2S (RH) terminal B and power supply

-

HO2S (RH) terminal B and body ground

-

HO2S (RH) terminal C and body ground

-

HO2S (RH) terminal D and power supply

-

HO2S (LH) terminal A and power supply

-

HO2S (LH) terminal A and body ground

-

HO2S (LH) terminal B and power supply

-

HO2S (LH) terminal B and body ground

Front Heated Oxygen Sensor (HO2S) Inspection|Page 2365 > < Front Heated Oxygen Sensor (HO2S) Inspection|Page 2363