CX-9 AWD V6-3.7L (2008)
Technical Service Bulletin # 0104608
Date: 081001
Remote Start System - Blows A/C and Ign. Fuses
Bulletin No.: 01-046/08
Last Issued: 10/1/2008
Subject:
REMOTE START CAUSES HVAC1 OR IGN1 FUSE TO BLOW - INSTALL LOAD REDUCTION RELAY SERVICE HARNESS
APPLICABLE MODEL(S)/VINS
2007-2008 CX-7
2007-2008 CX-9
DESCRIPTION
Some vehicles equipped with accessory remote start may experience an inoperative wiper/washers and/or the HVAC system after starting the vehicle
using the remote start feature. After the customer enters the vehicle and manually turns the ignition switch to the ON position, the wiper/washers and the
HVAC system will be operational.
The cause may be the wipers were left in the ON or AUTO position during an overnight freeze. The wipers will freeze to the windshield and cause an
electrical overload as the wipers attempt to operate after starting the vehicle using the remote start feature. The HVAC1 fuse and/or the IGN1 fuse
located in the remote start module will blow to protect the system during the electrical overload causing the wiper/washers and/or the HVAC system to
be inoperative.
IMPORTANT:
^
Once the customer enters the vehicle and manually turns the ignition switch to the ON position, the wiper/washers and the HVAC system will be
operational. The fault is contained in the remote start module and does not effect normal operation of the wiper/washers and the HVAC system
once the ignition is turned on. After the ignition is turned on, the wiper/washers and the HVAC system are powered as designed through the
vehicles electrical system. Customers having this concern should have their vehicle repaired using the following repair procedure.
PART(S) INFORMATION
WARRANTY INFORMATION
Disclaimer