Canister Purge Solenoid: Testing and Inspection

PURGE SOLENOID VALVE INSPECTION

Airflow Inspection

NOTE:  Perform the following test only when directed.

1. Disconnect the negative battery cable.
2. Remove the purge solenoid valve

3. Inspect airflow between the ports under the following conditions.

-

If not as specified, replace the purge solenoid valve.

-

If as specified, carry out the "Circuit Open/Short Inspection".

Circuit Open/Short Inspection

1. Disconnect the PCM connector.

2. Inspect the following wiring harnesses for an open or short circuit (continuity check).

Open circuit

-

If there is no continuity, there is an open circuit. Repair or replace the wiring harness.
-

Purge solenoid valve terminal B and PCM terminal 4T

-

Purge solenoid valve terminal A and main relay terminal C.

Short circuit

-

If there is continuity, there is a short circuit. Repair or replace the wiring harness.
-

Purge solenoid valve terminal B and body Ground

-

Purge solenoid valve terminal A and power supply