Neutral Safety Switch: Testing and Inspection

NEUTRAL SWITCH INSPECTION

NOTE:  Perform the following inspection only when directed

Continuity Inspection

1. Disconnect the negative battery cable
2. Remove the neutral switch (See MANUAL TRANSAXLE REMOVAL/INSTALLATION [G35M-R])

3. Inspect for continuity between the neutral switch terminals using an ohm meter

-

If the neutral switch is okay, but PID value is out of specification, perform the "Circuit Open/Short Inspection"

-

If not as specified replace the neutral switch Specification

Circuit Open/Short Inspection

1. Disconnect the PCM connector (See PCM REMOVAL/INSTALLATION)

2. Inspect the following harnesses for open or short circuit (Continuity check)

Open circuit

-

If there is no continuity, there is an open circuit. Repair or replace the harness
-

Neutral switch terminal B (harness-side) and PCM terminal 1W (harness-side)

-

Neutral switch terminal A (harness-side) and body GND

Short circuit

-

If there is no continuity, there is a short circuit Repair or replace the harness
-

Neutral switch terminal B (harness-side) and body GND