Millenia V6-2255cc 2.3L DOHC (1995)
Brake Fluid Pressure Sensor/Switch: Testing and Inspection
1. Disconnect sensor connector, then connect a suitable ohmmeter across connector terminals.
2. With brake fluid level above "minimum" mark, ensure continuity does not exist.
3. Remove enough brake fluid to drop level below "minimum" mark, then ensure continuity exists.
4. If results are not as specified, replace brake fluid level sensor.