Millenia L V6-2.5L DOHC (1997)
Temperature Sensor (Gauge): Testing and Inspection
Removal
1. Disconnect the water temperature sender unit connector.
2. Remove the water temperature sender unit.
Inspection
1. Remove the water temperature sender unit.
2. Place the sender unit in a container of water.
3. Heat the water gradually, and measure the resistance of the sender unit.
4. If riot as specified, replace the water temperature sender unit.
Installation
1. Apply sealant from the third thread to top thread.
2. Install the water temperature sender unit.
Tightening torque: 6.4-9.3 Nm (57-82 in.lbs.)
3. Connect the water temperature sender unit connector.