Millenia L V6-2.5L DOHC (1997)
Refrigerant Pressure Sensor / Switch: Service and Repair
Removal / Installation
1. Discharge the refrigerant from the system.
2. Disconnect the refrigerant pressure switch connector.
3. Remove the refrigerant pressure switch from cooler pipe No.3.
Immediately plug all open fittings to keep moisture out of the system.
4. Install in the reverse order of removal, referring to Installation note.
5. Charge the system and test its performance.
NOTE: Apply compressor oil to the O-rings and connect.