Millenia L V6-2.5L DOHC (1997)
NOTE: Set the difference between the center of the solar battery and that of the fluorescent lights below 500 mm (19.7 in).
7. Measure the voltage at terminal A of the solar cell.
Voltage: 6 V min.
8. If the voltage is less than 6 V, replace the glass panel.