Millenia L V6-2.5L DOHC (1997)
1.
Remove instrument cluster assembly without disconnecting the connectors.
2.
Turn key "ON" and measure the voltage between the following wires on the backside of the instrument cluster. Refer to illustration.
MEASURE VOLTAGES BETWEEN:
^
-
RED AND BLACK WIRE TERMINALS
^
-
BLUE AND BLACK WIRE TERMINALS
If the voltages are the same, an internal short exists. Replace print plate # 2.
If the voltages are different, proceed to STEP 3.
3.
Disconnect the three(3) wiring harness connectors on the back of the instrument cluster as illustrated above. Measure the resistance between the
wires screwed to the back of the instrument cluster. Use the illustration and the specifications. Replace the fuel meter if out-of-specification.