Millenia L V6-2.5L DOHC (1997)
Ignition Cable: Testing and Inspection
CAUTION: Reinstall the high-tension leads to their original positions. Incorrect installation can dam the leads and cause power loss, and negatively
effect electronic components.
Inspection
1. Measure the resistance of the high-tension leads.
Specification: 16 k-ohms per 1.00 m (3.28 ft)
2. If not as specified, replace the high-tension lead.