Millenia L V6-2.5L DOHC (1997)
ABS Main Relay: Testing and Inspection
Motor Relay
1. Measure the resistance between terminals E and H, or between A and H of the ABS relay connector.
^
Resistance: 50-90 Ohms
2. Check for continuity between terminals B and F.
^
There should be not continuity between terminals B and F.
3. Apply 12 V to terminals g (+) and h (-). Check for continuity between terminals B and F.
^
There should be continuity between terminals B and F.
4. If not as specified, replace the ABS relay.