mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Shift Interlock Solenoid > < Electrical Specifications|Page 2918
Page 1
background image

Pressure Regulating Solenoid: Testing and Inspection

PRESSURE CONTROL SOLENOID INSPECTION

1. Connect the (+) terminal of a dwell meter to terminal 1F of the transaxle control module and the (-) terminal to a ground. Set the dwell meter

selector to the 4 cylinder position.

2. Turn the ignition switch to ON.

NOTE:  The dwell meter indicates the OFF duty ratio.

3. Verify the duty ratio by depressing and releasing the accelerator pedal.

NOTE:  Refer to the table for relationship between the dwell angle (0) and duty ratio (%).

4. Depress the accelerator pedal slowly and verify that the duty ratio changes as shown in the graph.
5. If not as specified, check the transaxle control module, dropping resistor, and pressure control solenoid.

RESISTANCE

1. Disconnect the negative battery cable.
2. Remove the air cleaner assembly.
3. Disconnect the solenoid valve connector.

4. Measure the resistance between terminals A through G and a ground.

5. If not correct, check the wiring harness or replace the solenoid valve(s), if necessary.
6. Connect the solenoid valve connector.
7. Install the air cleaner assembly.
8. Connect the negative battery cable.

Shift Interlock Solenoid > < Electrical Specifications|Page 2918