Millenia L V6-2.5L DOHC (1997)
Input/Turbine Speed Sensor: Component Tests and General Diagnostics
INSPECTION OF RESISTANCE
1. Disconnect the input/turbine speed sensor connector.
2. Measure the resistance between the terminals of the input/turbine speed sensor. Resistance should be within 253 - 604 ohms at a fluid temperature
of -40 - 160°C (-40 - 320°F).
3. If not correct, replace the input/turbine speed sensor.
4. Connect the input/turbine speed sensor connector.