Standard Voltage

3. Measure the voltage at the terminals as indicated in the table using a voltmeter.

Standard Current (Reference)

4. Measure the current at terminal B as indicated in the table using an ammeter.

-

If not as specified, replace the generator.

NOTE:
-

The values are measured with the battery fully charged.

-

As the battery discharges, the current becomes greater.

-

When the measuring condition is "electrical load ON", turn all the following electrical systems on.
1. Headlight (high beam)
2. A/C (max.)
3. Brake light
4. Cooling fan
5. Condenser fan

Alternator|Service and Repair > < Alternator|Specifications|Page 3174