mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Shifter A/T|Testing and Inspection|Page 2725 > < Shifter A/T|Testing and Inspection
Page 1
background image

Shifter A/T: Adjustments

SELECTOR LEVER ADJUSTMENT 

Selector Cable 
1. Remove the air cleaner component.
2. Shift the selector lever to the P position.

3. Loosen nut A shown in the figure.
4. Push the selector cable in the direction of the arrow until it doesn't move any further.

5. Position the selector cable so that there is no load in the direction of the arrows, and tighten the nut.

Tightening torque
16 - 22 Nm (1.6 - 2.3 kgf.cm, 12 - 16 ft. lbs.) 

6. Install the air cleaner component.
7. Shift the selector lever from the P position to L range, and make sure that there is no interference from other components in that area.

Indicator Panel 
1. Shift the selector lever to the P position.
2. Loosen the indicator panel screws.

3. Align the alignment screw in the slider with the holes in the indicator panel. Install suitable heavy-gauge wire to hold the slider.

4. Tighten the indicator panel screws in the order shown in the figure.

Tightening torque
2.0 - 2.9 Nm (20 - 30 kgf.cm, 18 - 26 inch lbs.) 

Shifter A/T|Testing and Inspection|Page 2725 > < Shifter A/T|Testing and Inspection