Millenia S V6-2.3L DOHC (Miller cycle) (2000)
Washer Fluid Level Indicator: Service and Repair
1. Disconnect the negative battery cable.
2. Remove the splash shield.
3. Extract the washer fluid.
4. Disconnect the connector.
5. Remove the washer fluid-level sensor.
6. Remove the grommet.
7. Install in the reverse order of removal.