Blower Motor Switch: Technical Service Bulletins
Blower Motor Switch - Continues Running W/Switch OFF

Category 15
Applicable Model/s 1990 MX-5 Miata
Subject BLOWER MOTOR SWITCH
Bulletin No.

083/89

Issued

10/12/89

Revised
DESCRIPTION

If you encounter a complaint of the blower motor running while the blower switch is OFF but the IG switch is ON, the wiring harness may be grounded
in the area shown below. This is caused by unprotected wires rubbing on the dash frame behind the audio unit.

The protector instaffed in this area has been lengthened for more reliable protection since the production date of July 1, 1989.

VIN OF PRODUCTION CHANGE

JM1NA3511L0111862

July 1, 1989

REPAIR PROCEDURE

If you encounter the above mentioned complaint, remove the audio unit and inspect the area shown for short circuit. Repair the wire harness if necessary.