voltage should be 0 volts just after the ignition switch is turned off.  After 2-5 seconds, the voltage should momentarily reach 8-12 volts and then
return to 0 volts.

Air Flow Meter Removal

8.  

If as specified, replace the air flow sensor.

9.  

If not as specified, check the voltage at the engine control unit terminals "2E", "2I", and "2J", and the related wiring harness (Refer to ENGINE
CONTROL UNIT
).