MPV 4WD V6-3.0L SOHC (1990)
Starter Solenoid: Testing and Inspection
Pull-In Test
For the following procedure, it is necessary to remove starter magnetic switch from starter.
1.
Connect battery positive to S terminal of magnetic switch. Ground magnetic switch M terminal.
2.
Ensure plunger is pulled into switch.