MPV DX V6-2.5L DOHC (2000)
Ignition Cable: Service and Repair
CAUTION:
-
The high-tension leads must be reinstalled to their original positions. Incorrect installation can damage the leads and cause power loss, and
negatively affect the electronic components.
-
Pulling on the wire part of the high-tension lead may break it. To remove the leads, pull only on the plug cap.
1. Disconnect the negative battery cable.
2. Disconnect the high-tension lead connected to ignition coil.
3. Remove the ignition coil.
4. Remove the IMRC actuator with the IMRC cable still connected. Position the IMRC actuator so that it is out of the way.
5. Remove the high-tension lead.
6. Install in the reverse order of removal.