MPV DX V6-2.5L DOHC (2000)
Operation
-
When the selector lever is moved, the manual valve moves also, until it is located in a position where line pressure (7) is distributed to each line
pressure circuit for P. R. and N positions and D, 2, and 1 ranges. Line pressures (1), (3), (5), and (6) are distributed to each valve. When line
pressure (7) is not in a distribution position, the line pressures (1), (3), (5), and (6) are drained at the X position.
Line Pressure (1)
-
1-2 shift valve
-
2-3 shift valve
-
3-4 shift valve
-
N-D accumulator
-
Forward clutch
-
TCC control valve
Line pressure (3)
-
2-3 shift valve
Line Pressure (5)
-
Low reducing valve
Line Pressure (6)
-
1-2 shift valve
-
N-R accumulator
-
Reverse clutch
-
Low and reverse brake
2-3 Accumulator
2-3 ACCUMULATOR
Outline
-
The 2-3 accumulator reduces shift shock generated during 2GR - 3GR shifting by moderating a rapid increase in hydraulic pressure when the 3-4
clutch is engaged.