mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 2228 > < Component Tests and General Diagnostics
Page 2
background image

2. Connect a fuel pressure gauge between the fuel filter (high pressure side) and fuel distributor.
3. Connect the negative battery cable.

4. Connect the data link connector terminals F/P and GND by using a jumper wire.
5. Turn the ignition switch to ON for approx. 10 sec. to operate the fuel pump.
6. Turn off the ignition switch. Wait for 5 min., and measure the fuel pressure.

Specification:  More than 150 kPa (21 psi) 

7. Disconnect the jumper wire.

8. If the pressure is lower than specified, measure the fuel line pressure while pinching the return hose.

-

If the fuel line pressure holds, replace the pressure regulator. (Refer to FUEL PRESSURE REGULATOR/SERVICE AND REPAIR.)

-

If the fuel line pressure does not hold, check the fuel pump fuel pressure hold.
If the fuel pump fuel pressure hold is normal, check the fuel leaks from fuel line and fuel injector.

9. If the pressure is as specified, check the fuel leakage from fuel line and fuel injector.

Injector Troubleshooting

Component Tests and General Diagnostics|Page 2228 > < Component Tests and General Diagnostics