MPV LX V6-2.5L DOHC (2000)
Radiator Cooling Fan Motor: Testing and Inspection
Component Inspection
COOLING FAN MOTOR INSPECTION
1. Verify that the battery is fully charged.
2. Connect battery voltage and an ammeter to the cooling fan motor connector.
3. Perform the same procedure as Step 2 for the additional fan motor (if equipped).
4. Verify that the cooling fan motor operates smoothly at the standard current draw.
^
If not as specified, replace the cooling fan motor.
Standard current
High: 11.8 - 14.8 (A) [12V]
Low: 6.8 - 9.8 (A) [12V]