mazda Workshop Repair Guides

Mazda MPV Workshop Service and Auto Repair Manual - V6 25L DOHC

Climate Control Unit <--> [Control Module HVAC] > < Condenser HVAC|Testing and Inspection
Page 1
background image

Condenser HVAC: Service and Repair

1. Disconnect the negative battery cable.
2. Evacuate the refrigerant from the system.
3. Remove the radiator grille.

CAUTION:
-

If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always
immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign material out of the cycle.

-

Do not allow A/C compressor oil to spill. Operating the A/C compressor without sufficient A/C compressor oil can lead to abnormal noise and
cause the A/C compressor to seize up.

4. Remove in the order indicated in the table.
5. Install in the reverse order of removal.
6. Perform the refrigerant system performance test.

Condenser Installation Note

1. When installing a new condenser, add a supplemental amount of ND-OIL8 compressor oil from the inlet.

Supplemental amount 
40 ml {40 cc, 1.4 fl oz}

Climate Control Unit <--> [Control Module HVAC] > < Condenser HVAC|Testing and Inspection