mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Ignition Cable|Specifications|Page 521 > < Ignition Cable|Specifications
Page 1
background image

Ignition Cable: Testing and Inspection

1. Measure the resistance of the high-tension lead by using an ohmmeter.

Specification
No.1 lead: 7-18 k Ohms
No.2 lead: 2-7  k Ohms
No.3 lead: 8-21 k Ohms
No.4 lead: 4-10 k Ohms
No.5 lead: 0-22 k Ohms
No.6 lead: 5-12 k Ohms
 

2. If not as specified, replace the high-tension lead

Ignition Cable|Specifications|Page 521 > < Ignition Cable|Specifications