MPV LX 2WD V6-3.0L SOHC (1998)
9. If generator terminal B current will not increase, disassemble and inspect the generator.
Generator Inner Parts
Rotor
1. Wiring damage
1. Measure the resistance between the slip rings by using an ohmmeter.
Specification
2.4 - 2.9 Ohms [20 °C (68 °F)]
2. If it is not within the specification, replace the rotor.
2. Ground of field coil
1. Check for no continuity between the slip ring and the core by using an ohmmeter.
2. Replace the rotor if there is continuity.
3. Slip ring surface
If the slip ring surface is rough, use a lathe or fine sandpaper to repair it.
Stator
1. Wiring damage
1. Check for continuity between the stator coil leads by using an ohmmeter.
2. Replace the stator if there is no continuity.