mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Control Assembly, HVAC|Testing and Inspection|Page 3785 > < Control Assembly, HVAC|Testing and Inspection
Page 1
background image

Control Assembly: Adjustments

ADJUSTMENTS

Air Mix Wire

1.  Set the temperature control lever to MAX HOT
2.  Connect and clamp the wire with the shutter lever on the heater unit all the way to the right.
3.  Move the temperature control lever to make sure the wire is securely attached and that it moves fully from HOT to COLD.

Airflow Mode Wire

1.  Set the mode lever to VENT
2.  Connect and clamp the wire with the shutter lever on the heater unit at its closest point.
3.  Move the mode lever to make sure the wire is securely attached and that it moves fully from DEF to VENT.

Rec/Fresh Wire

1.  Set the REC/FRESH lever to FRESH.
2.  Connect and clamp the wire with the shutter lever on the blower unit at its closest point.
3.  Move the REC/FRESH lever to make sure the wire is securely attached and that it moves fully from REC to FRESH.

Control Assembly, HVAC|Testing and Inspection|Page 3785 > < Control Assembly, HVAC|Testing and Inspection