Evaporator Temperature Sensor / Switch: Testing and Inspection

On-Vehicle Inspection

1.  Remove the glove compartment. 
2.  Run the engine at idle.

3.  Turn the A/C switch off and set the fan switch at 4 to operate the blower fan for a few minutes.
4.  After a few minutes, turn the fan switch off and stop the engine.

Note: The thermoswitch contacts will be open if the evaporator temperature is below 0-2°C { 32-35°F }.

5.  Disconnect the thermoswitch connectors and check for continuity between the switch terminals.
6.  If there is no continuity, replace the thermoswitch.

Component Inspection

1.  Immerse the sensing bulb in a container of ice water.
2.  Check the switch operation as specified in the figure.
3.  If not as specified, replace the thermoswitch.