mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 994 > < Initial Inspection and Diagnostic Overview|Page 992
Page 3
background image

4. Inspect for continuity between FP connector terminals B and D.

-

If there is no continuity, replace the FP body.

-

If as specified but the Simulation Test is failed, carry out the "Circuit Open/Short Inspection".

Circuit Open/Short Inspection

1. Inspect the following wiring harness for open or short. (Continuity check).

Open circuit

-

If there is no continuity, the circuit is open. Repair or replace the harness.
-

GND circuit (FP connector terminal D and body GND)

-

Power circuit (fuel pump relay (FP RLY) connector terminal C and FP connector terminal B through common connector)

Short circuit

-

If there is no continuity, the circuit is shorted. Repair or replace the harness.
-

FP RLY connector terminal C and FP connector terminal B through common connector to GND

Fuel Pump (FP) Pressure Inspection

WARNING:  Fuel line spills and leakage are dangerous. Fuel can ignite and cause serious injuries or death and damage. Always carry out the
following procedure with the engine stopped.

CAUTION:  Disconnecting/connecting the quick release connector without cleaning it may possibly cause damage to the fuel pipe and quick release
connector. Always clean the quick release connector joint area before disconnecting/connecting using a cloth or soft brush, and make sure that it is free
of foreign material.

NOTE:  Perform the following test only when directed.

1. Complete the "BEFORE REPAIR PROCEDURE". 
2. Disconnect the negative battery cable.
3. Lift up the vehicle with safety stands.
4. Remove the fuel filter cover.
5. Inspect that the quick release connector point area is free of foreign materials.
6. Clean as necessary.

Initial Inspection and Diagnostic Overview|Page 994 > < Initial Inspection and Diagnostic Overview|Page 992