mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Component Inspection|Page 1757 > < Canister Purge Solenoid|Locations
Page 1
background image

Canister Purge Solenoid: Testing and Inspection
Component Inspection

PURGE SOLENOID VALVE INSPECTION

Simulation Test

1. Carry out the "Purge Control Inspection". 

-

If not as specified, perform the further inspection for the purge solenoid valve.

Airflow inspection

NOTE:  Perform the following test only when directed.

1. Remove the purge solenoid valve. 

2. Inspect airflow between the ports under the following conditions.

-

if as specified but the "Purge Control Inspection" is failed, inspect the vacuum hoses for improper routing, kinks or leakage, and inspect
"Circuit Open/Short Inspection".

-

If not as specified, replace the purge solenoid valve.

Circuit Open/Short Inspection

Open circuit

-

GND circuit (Purge solenoid valve connector terminal B and PCM connector terminal 3C through common connector)

-

Power circuit (Purge solenoid valve connector terminal A and main relay connector terminal D through common connector)

Short circuit

-

Purge solenoid valve connector terminal B and PCM connector terminal 3C to GND.

Component Inspection|Page 1757 > < Canister Purge Solenoid|Locations