Location of Fuel Tank One Way Valve on 2001 MX-5 Miata LS (18L DOHC)
Fuel Tank One Way Valve: Testing and Inspection
NONRETURN VALVE INSPECTION
1. Siphon the fuel from the fuel tank.
2. Remove the FP. (See FUEL PUMP (FP) REMOVAL/INSTALLATION.)
NOTE:
-
Nonreturn valve is integrated in the fuel tank
-
The nonreturn valve is normally closed by the spring force.
3. Verify that the nonreturn valve is closed.
-
If the nonreturn valve is stuck open will not open even when pulled up by a finger, replace the fuel tank.