7. Set the SST to the fuel filter outlet pipe and push into the quick release connector, and disconnect the fuel pipe.

-

If removal of the retainer is required, remove it by squeezing the tabs of the retainer.

CAUTION:  
-

Removing the retainer from the disconnected fuel pipe will reduce the effectiveness of the retainer. The retainer must be replaced when any of
the following applies.
1. Scratches or damage is observed on the retainer.
2. Fuel pipe has been replaced.
3. Fuel filter (high-pressure) has been replaced.

8. Cover the disconnected quick release connector to prevent them from being scratched or contaminated with foreign material.

9. Turn the lever as shown to plug the SST outlet.

11. Connect a fuel hose and clamp to the SST outlet pipe.
12. Set the fuel hose into a container to avoid fuel spills.
13. Pull the quick release connector by hand and verify that it is installed securely.
14. Connect the negative battery cable.

CAUTION:  Connecting the wrong DLC terminals may possibly cause a malfunction. Carefully connect the specified terminals only.

15. Short the DLC terminals F/P and body GND using a jumper wire.

Initial Inspection and Diagnostic Overview|Page 1370 > < Initial Inspection and Diagnostic Overview|Page 1368