mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Evaporator Temperature Sensor / Switch|Testing and Inspection|Page 250 > < Blower Motor Switch|Testing and Inspection
Page 1
background image

Evaporator Temperature Sensor / Switch: Testing and Inspection

THERMOSWITCH INSPECTION

To Determine If The Switch Is Functioning

1. Remove the glove compartment.
2. Start the engine.
3. Turn the A/C switch on.
4. Turn the fan switch on.

5. Connect the positive (+) and negative (-) probes of the voltmeter to terminal A and terminal B of the thermoswitch respectively. (The wiring

harness connector must be connected to the thermoswitch connector.)

6. Inspect the voltage as shown.

-

If not as specified, inspect on/off points of the thermoswitch.

To Inspect On/Off Points of the Thermoswitch

1. Disconnect the negative battery cable.
2. Remove the cooling unit.
3. Remove the thermoswitch.
4. Connect the negative battery cable.
5. Connect the thermoswitch connector to the wiring harness connector.
6. Turn the ignition switch to ON position.
7. Turn the A/C switch on.
8. Turn the fan switch on.

9. Immerse the sensor part of thermoswitch in a container of ice water.

10. Connect the positive (+) and negative (-) probes of the voltmeter to terminal A and terminal B of the thermoswitch respectively.

Evaporator Temperature Sensor / Switch|Testing and Inspection|Page 250 > < Blower Motor Switch|Testing and Inspection