22. Check the camshaft pulley for damage and cracks.

Circuit Open/Short Inspection

Open circuit

-

If there is no continuity, the circuit is open. Repair or replace the harness.
-

CMP circuit (CMP sensor connector terminal B and PCM connector terminal 3V.)

-

Power circuit (CMP sensor connector connector terminal A and main relay terminal D through common connector.)

-

GND circuit (CMP sensor terminal C and body GND.)

Short circuit

-

If there is continuity, the circuit is shorted. Repair or replace the harness.
-

CMP sensor connector terminal B and PCM connector terminal 3V to ground.

-

CMP sensor connector terminal A and main relay terminal D through common connector to GND.