mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Tune-up and Engine Performance Checks > < Variable Valve Timing Actuator|Testing and Inspection
Page 1
background image

Variable Valve Timing Solenoid: Testing and Inspection

Inspection Using An Oscilloscope (Reference)

Oil control valve (OCV) signal

-

PCM terminal: 4D (+) <-> 4A (-)

-

Oscilloscope setting: 2.0 V/DIV (Y), 0.5 ms/DIV (X), DC range

-

Vehicle condition: Idling after warm-up (no electrical load)

Tune-up and Engine Performance Checks > < Variable Valve Timing Actuator|Testing and Inspection