1. Set the SST into the clamp with the arrow mark on the clamp facing the SST.

2. Push the SST with your thumb until the clamp clicks.

CAUTION:  If the SST is pushed with excessive force, the clamp will deform. Be careful when pushing the SST into the clamp.

3. Pull up the stopper, then pull the SST from the pipe.
4. Remove the SST from the clamp.

CAUTION:  Be careful not to bend the SST needles when performing a clamp removal. If the needles are bent, the clamp can not be unlocked.

Refrigerant Lines Installation Note

1. Apply compressor oil to the O-rings and connect the joints.
2. When installing a new cooler hose or pipe add DENSO OIL9 compressor oil into the refrigeration cycle.

Supplemental amount (approximate quantity) 10 ml {10 cc, 0.3 fl oz}

3. Tighten the joints.

1. Tighten the nut or bolt of the joint by hand.
2. Tighten the joint to the specified torque.

-

If it is a nut joint, tighten the nut using a spanner and torque wrench.