MX-5 Miata Mazdaspeed L4-1.8L DOHC Turbo (2004)
Idle Speed/Throttle Actuator - Electronic: Oscilloscope Patterns and Waveforms
Inspection Using An Oscilloscope (Reference)
IAC control signal
-
PCM terminal: 2P (+) <-> 2Q (-)
-
Oscilloscope setting: 2.0 V/DIV (Y), 25 ms/DIV (X), DC range
-
Vehicle condition: Idling after warm-up (no electrical load)