mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Leak Detection Pump, Evaporative System|Testing and Inspection|Page 1623 > < Leak Detection Pump, Evaporative System|Testing and Inspection
Page 2
background image

-

If not as specified, replace the EVAP system leak detection pump.

-

If as specified, carry out the "Circuit Open/Short Inspection".

Circuit Open/Short Inspection 

Open circuit

-

If there is no continuity, the circuit is open. Repair or replace the harness.
-

EVAP system leak detection pump terminal C (harness-side) and PCM terminal 4AH

-

EVAP system leak detection pump terminal D (harness-side) and PCM terminal 3K

-

EVAP system leak detection pump terminal A (harness-side) and main relay terminal D (harness-side)

-

EVAP system leak detection pump terminal B (harness-side) and the body GND

Short circuit

-

If there is continuity, the circuit is shorted. Repair or replace the harness.
-

EVAP system leak detection pump terminal C (harness-side) and power supply

-

EVAP system leak detection pump terminal D (harness-side) and power supply

-

EVAP system leak detection pump terminal A (harness-side) and the body GND

-

EVAP system leak detection pump terminal B (harness-side) and power supply

Leak Detection Pump, Evaporative System|Testing and Inspection|Page 1623 > < Leak Detection Pump, Evaporative System|Testing and Inspection