mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Sensors and Switches - Fuel Delivery and Air Induction > < Main Relay (Computer/Fuel System)|Locations|Page 1837
Page 1
background image

Rollover Valve: Testing and Inspection

FUEL SHUT-OFF VALVE/ROLLOVER VALVE INSPECTION

CAUTION:  Disconnecting/connecting the quick release connector without cleaning it may possibly cause damage to the fuel pipe and quick release
connector. Always clean the quick release connector joint area before disconnecting/connecting using a cloth or soft brush, and make sure that it is free
of foreign material.

1. Disconnect the plastic fuel hose and the FP unit connector. (See FUEL PUMP (FP) REMOVAL/INSTALLATION.)
2. Remove the fuel tank with the FP unit. (See FUEL TANK REMOVAL/INSTALLATION.)
3. Plug the fuel main pipe and fuel return pipe of the FP unit.

4. Plug port A.
5. Level the fuel tank.
6. Blow through port B and verify that there is airflow from port C.

-

If there is no airflow, replace the fuel tank.

-

If there is airflow, plug port C and proceed to Step 7.

7. Blow through port B and verify that there is airflow from port A.

-

If there is no airflow, replace the fuel tank.

-

If there is airflow, turn the fuel tank upside-down, and proceed to Step 8.

8. Blow through port B and verify that there is no airflow from port A.

-

If there is airflow, replace the fuel tank.

Sensors and Switches - Fuel Delivery and Air Induction > < Main Relay (Computer/Fuel System)|Locations|Page 1837